• mile米乐(中国)

    Rapid extraction of total lipids from microalgae

    Ying-Yu Hu, Zoe V. Finkel

    Published: 2022-06-08 DOI: 10.17504/protocols.io.dm6gpr9jdvzp/v4
    AI 解读
    浏览 1629

    Abstract

    In this protocol, total lipids from miroalgae is extracted with Folch solvent (2:1 chloroform-methanol v/v) and the addition of 5% water. Filter and cell debris is commonly removed by filtration, which is laborious and time consuming. It is also the main reason to either cause sample loss and therefore underestimation; or contamination from filtration system and therefore overestimation. We now use centrifugation to remove filter debris. The extract is then mixed with 0.88% potassium chloride solution to form a biphasic system, where in between the two phases is the thin distinct cell debris layer. The lower phase with extracted lipids is collected and dried under N2gas flow. The residue is stored under -80 ºC for further measurement.

    Citation
    FOLCH J, LEES M, SLOANE STANLEY GH A simple method for the isolation and purification of total lipides from animal tissues J Biol Chem, 1957, 226, 497-509

    Citation
    Axelsson M, Gentili F 2014 A single-step method for rapid extraction of total lipids from green microalgae. PloS one http://doi.org/10.1371/journal.pone.0089643

    Before start

    Steps

    Collect microalgae samples

    1.

    Precombust GFF filter at 450°C for 4h 0m 0s

    2.

    Rinse forceps with 95% ethanol, air-dry.

    Equipment

    ValueLabel
    Filter forcepsNAME
    blunt end, stainless steelTYPE
    MilliporeBRAND
    XX6200006PSKU
    http://www.emdmillipore.com/LINK

    Note
    Wipe-dry forceps can cause carbon contamination of samples.

    3.

    Filter microalgae in liquid media onto precombusted GFF filters, using gentle vacuum pressure (5 inches Hg).

    4.

    Rinse sample with filtered seawater

    5.

    Place sample filters in cryogenic vials

    6.

    Filter blank media (without cells) through precombusted GFF filter as blank.

    7.

    Flash freeze filters and stored at -80°C

    8.

    Freeze dry before measurement.

    Equipment

    ValueLabel
    FreeZone® 2.5 L Benchtop Freeze DryersNAME
    Labconco®BRAND
    700202000SKU
    9.

    Follow protocol to hydrolyze the sample.

    Hydrolysation treatment can improve the extraction efficiency:

    Prepare glassware

    10.

    Precombust the centrifuge tubes, scintillation vials and storage vials at 500°C for 6h 0m 0s

    11.

    Precombust pasteur pipets at 500°C for 2h 0m 0s

    Equipment

    ValueLabel
    Disposable Soda-Lime Glass Pasteur PipetsNAME
    5 3/4"TYPE
    FisherbrandBRAND
    13-678-6ASKU
    http://www.fishersci.com/us/en/home.htmlLINK
    12.

    Rinse caps with 95% ethanol and air-dry prior to use

    13.

    Rinse serological pipets and the reagent bottle for dichromate reagent with 95% ethanol until there is not stain and with chloroform for the final rinse. Air-dry.

    Equipment

    ValueLabel
    VWR® Volumetric Pipets, Reusable, Color Coded, Class ANAME
    0.5 mL and 5 mLTYPE
    VWRBRAND
    10546-004 and 10546-014SKU

    Equipment

    ValueLabel
    PYREX® Media BottlesNAME
    Corning®BRAND
    1395-100SKU
    14.

    Latex bulbs are required for Pasteur pipets

    Prepare reagent

    15.

    Folch solvent (CHCl3: MeOH=2:1 v/v)

    15.1.

    Mix two parts of chloroform and one part of methanol in a 1 L amber bottle. Log the volume of each solvent for double checking the ratio.

    AB
    Chloroform (mL)
    Methanol (mL)
    15.2.

    Attach dispensette to the bottle, mix well.

    Equipment

    ValueLabel
    Bottle-top dispenserNAME
    BrandTech Dispensette® SBRAND
    4731330SKU
    15.3.

    Label bottle with MSDS label.

    16.

    KCl solution (0.88% )

    16.1.

    Weigh the pyrex media bottle and tare.

    Equipment

    ValueLabel
    PYREX® Media BottlesNAME
    Corning®BRAND
    1395-100SKU
    16.2.

    Directly weigh 0.44g KCl in the bottle.

    16.3.

    Top bottle with MilliQ water to 50g

    AB
    KCl (g)
    Final (g)

    Extraction

    17.

    If lipids samples are not processed for carbohydrate, transfer freeze dried samples and blanks into muffled centrifuge tubes

    Note
    It takes about 7 to 8 hours to process 16 samples.

    Equipment

    ValueLabel
    Disposable Glass Screw-Cap Centrifuge TubesNAME
    10 mLTYPE
    Corning®BRAND
    99502-10SKU

    Equipment

    ValueLabel
    Polypropylene Screw CapsNAME
    Linerless, 15-415TYPE
    Kimble ChaseBRAND
    73805-15415SKU
    17.1.

    Add 100µL MilliQ directly onto the sample.

    17.2.

    Freeze at -80°C 0h 10m 0s

    17.3.

    Remove vials from freezer.

    17.4.

    Purge the dispensette, fill the tubing with solvent before dispensing solvent into sample tube.

    17.5.

    Dispense 2.0mL Folch solvent into sample tube.

    18.

    If lipids samples have been hydrolyzed for carbohydrate and solvent has already been added, go to the vortex step directly.

    19.

    Vortex 0h 28m 0s by using a tube insert.

    Equipment

    ValueLabel
    VWR ANALOG VORTEX MIXERNAME
    VWRBRAND
    10153-838SKU
    With tube insertSPECIFICATIONS
    20.

    Sonicate 0h 2m 0s

    21.

    Vortex 0h 30m 0s by using a tube insert.

    22.

    Prepare one set of precombusted tubes (#T1), label the tubes, cap is not required.

    Equipment

    ValueLabel
    Disposable Glass Screw-Cap Centrifuge TubesNAME
    10 mLTYPE
    Corning®BRAND
    99502-10SKU
    23.

    Place one pasteur pipet (#P1) into each tube

    Equipment

    ValueLabel
    Disposable Pasteur PipetNAME
    9 inchTYPE
    VWRBRAND
    14672-380SKU
    24.

    Prepare another set of precombusted tubes (#T2) for supernatant. Cap the tube to avoid contamination.

    Equipment

    ValueLabel
    Disposable Glass Screw-Cap Centrifuge TubesNAME
    10 mLTYPE
    Corning®BRAND
    99502-10SKU

    Equipment

    ValueLabel
    Polypropylene Screw CapsNAME
    Linerless, 15-415TYPE
    Kimble ChaseBRAND
    73805-15415SKU
    25.

    Work on eight samples first. Use the pasteur pipet (#P1) to gently lift the filter upwards and transfer liquid (as much as possible) to the centrifuge tube. Keep the pasteur pipet (#P1) in its corresponding empty tube (#T1).

    26.

    Add 50µL MilliQ and 1mL Folch solvent to the residue.

    27.

    Vortex the eight samples at the highest speed to loosen the filter.

    28.

    Vortex the eight samples by using a tube insert while transferring supernatant from another eight samples to centrifuge tubes.

    29.

    Sonicate 0h 2m 0s

    30.

    Vortex the second eight samples by using a tube insert while transferring supernatant from the first eight samples to centrifuge tubes.

    Note
    Same alternate routine for the following steps.

    31.

    Use the pasteur pipet (#P1) to gently lift the filter upwards and transfer all liquid to the centrifuge tube (#T1). Keep the pasteur pipet (#P1) in its corresponding empty tube (#T1).

    32.

    Add 50µL MilliQ and 1mL Folch solvent to the residue.

    33.

    Vortex while transferring supernatant from another set of samples to centrifuge tubes.

    34.

    Sonicate 0h 2m 0s

    35.

    Use the pasteur pipet (#P1) to gently lift the filter upwards and transfer all liquid to the centrifuge tube (#T1). Keep the pasteur pipet (#P1) in its corresponding empty tube (#T1).

    36.

    Add 50µL MilliQ and 1mL Folch solvent to the residue.

    37.

    Vortex while transferring supernatant from another set of samples to centrifuge tubes.

    38.

    Sonicate 0h 2m 0s

    39.

    Use the pasteur pipet (#P1) to gently lift the filter upwards and transfer all liquid to the centrifuge tube (#T1).

    40.

    Leave the pasteur pipet (#P1) in the tube with filter for a while, the tip gradually sucks liquid dripping from filter.

    41.

    Pipette the pasteur pipet in water layer up and down to rinse off organic extract. Put the pipet back in the tube with filter.

    Separation

    42.

    Centrifuge at 3200rpm

    Equipment

    ValueLabel
    General-purpose benchtop centrifugeNAME
    IEC CENTRA CL2TYPE
    ThermoBRAND
    00427 0FSKU
    43.

    Filter and cell debris stay between the two layer.

    44.

    Use pasteur pipet (#P1) to remove supernatant as much as possible. Do not disturb the debris.

    45.

    Return pipet (#P1) back to the tube with filter.

    46.

    Add 500 ul KCl solution, vortex and then centrifuge at 3200rpm

    Note
    Volume of Folch solvent to KCl is about 4 to 1.

    47.

    Use #P1 to remove supernatant as much as possible. Do not disturb the debris.

    48.

    Turn on heat block to 37°C , use a thermometer to monitor the actual temperature.

    Equipment

    ValueLabel
    LSE digital dry bath heaterNAME
    CorningBRAND
    6885-DBSKU

    Equipment

    ValueLabel
    Blocks for Corning® LSE Digital Dry Bath HeatersNAME
    CorningBRAND
    480124SKU
    49.

    Place tubes in the heater.

    Note
    Organic layer turns foggy when temperature is lower than 37°C

    50.

    Use a new pasteur pipet to transfer the lower organic phase to a clear 12 mL storage vial.

    Do not disturb the cell debris in between the two phases.

    Note
    If it has already been the end of the day, keep samples at -80°C

    Note
    Clear vial helps to check if there is water drops or impurities in lipids extract after dried.

    Equipment

    ValueLabel
    Glass Vials PTFE/SILiCone SEPTA ClearNAME
    16 mLTYPE
    Thermo ScientificBRAND
    B7990-4SKU
    http://www.fishersci.com/us/en/home.htmlLINK

    Equipment

    ValueLabel
    Screw Vial Convenience Kit, 12mL solid top PTFE capNAME
    Thermo ScientificBRAND
    B7800-12ASKU
    51.

    Dry organic phase extract at 37°C under a stream of N2 gas (<2 psi) for about 0h 30m 0s .

    ABC
    TimeGas cylinder pressure
    Start
    End

    Equipment

    ValueLabel
    Reacti-Vap EvaporatorNAME
    Thermo ScientificBRAND
    TS-18825SKU

    Purification

    52.

    The lipids extract might still have water residue (which can't be dried by nitrogen gas) or water soluble impurities.

    Redissolve it with 5mL chloroform by using glass serological pipet, transfer certain amount of chloroform dissolved extract for lipids measurement (based on the estimation, <100 ug) into a new vial. Log the actual volume transferred.

    Equipment

    ValueLabel
    SafetypetteNAME
    JenconsBRAND
    75856-442SKU
    53.

    Dry extract at 37°C under a stream of N2 gas (<2 psi) for about 0h 30m 0s (Generally 2 mL/5 min).

    ABC
    TimeGas cylinder pressure
    Start
    End
    54.

    Freeze dried extract and excess extract (in chloroform) at -80°C.